{"id":34569,"date":"2024-05-06T10:44:41","date_gmt":"2024-05-06T13:44:41","guid":{"rendered":"https:\/\/phelcom.com\/?p=34569"},"modified":"2024-10-02T11:38:36","modified_gmt":"2024-10-02T14:38:36","slug":"meibografia-para-diagnostico-de-olho-seco","status":"publish","type":"post","link":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/","title":{"rendered":"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco"},"content":{"rendered":"\n<p><\/p>\n\n\n\n<p>As gl\u00e2ndulas de Meib\u00f4mio, localizadas nas placas tarsais das p\u00e1lpebras, desempenham um papel fundamental na produ\u00e7\u00e3o da lip\u00eddica do filme lacrimal, que corresponde \u00e0 sua camada mais externa. Essa camada \u00e9 essencial para estabilizar o filme lacrimal prevenindo a evapora\u00e7\u00e3o da l\u00e1grima e contribuindo para a homeostase da superf\u00edcie ocular. A disfun\u00e7\u00e3o das gl\u00e2ndulas de meibomius (MGD), por sua vez, leva \u00e0 instabilidade do filme lacrimal, causando um desequil\u00edbrio na fisiologia da superf\u00edcie ocular.<\/p>\n\n\n\n<p>A&nbsp;MGD se d\u00e1 pela altera\u00e7\u00e3o da qualidade da secre\u00e7\u00e3o de meibomius, pela perda das gl\u00e2ndulas de meibomius (<em>\u201cdropout\u201d<\/em>) e\/ou pela obstru\u00e7\u00e3o dos ductos das gl\u00e2ndulas, por onde a secre\u00e7\u00e3o se exterioriza. Um dos testes mais \u00fateis para avalia\u00e7\u00e3o da morfologia das gl\u00e2ndulas de Meib\u00f4mio \u00e9 chamado de Meibografia, um m\u00e9todo que permite a visualiza\u00e7\u00e3o destas gl\u00e2ndulas <em>in vivo<\/em>.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Avalia\u00e7\u00e3o proped\u00eautica de olho seco: a principal, mas n\u00e3o a \u00fanica aplica\u00e7\u00e3o da meibografia<\/strong><\/h2>\n\n\n\n<p>Os testes diagn\u00f3sticos para avalia\u00e7\u00e3o de olho seco incluem a observa\u00e7\u00e3o de estabilidade e volume do filme lacrimal, avalia\u00e7\u00e3o de danos da superf\u00edcie ocular a partir de exames utilizando corantes vitais, como fluoresce\u00edna ou rosa bengala, e a avalia\u00e7\u00e3o das p\u00e1lpebras, incluindo o exame das gl\u00e2ndulas de meib\u00f4mio.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><a href=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_meibografia_saudavel.jpeg\" data-lbwps-width=\"1900\" data-lbwps-height=\"1600\" data-lbwps-srcsmall=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_meibografia_saudavel-300x253.jpeg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"862\" src=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_meibografia_saudavel-1024x862.jpeg\" alt=\"Img Meibografia Saudavel\" class=\"wp-image-34580\" style=\"width:544px;height:auto\" srcset=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_meibografia_saudavel-980x825.jpeg 980w, https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_meibografia_saudavel-480x404.jpeg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><figcaption class=\"wp-element-caption\">Meibografia realizada com luz infravermelha do retin\u00f3grafo port\u00e1til Eyer2<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><a href=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_infra_olho_seco_eyer2-1.jpg\" data-lbwps-width=\"1600\" data-lbwps-height=\"1318\" data-lbwps-srcsmall=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_infra_olho_seco_eyer2-1-300x247.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"844\" src=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_infra_olho_seco_eyer2-1-1024x844.jpg\" alt=\"Img Infra Olho Seco Eyer2 1\" class=\"wp-image-34600\" style=\"width:541px;height:auto\" srcset=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_infra_olho_seco_eyer2-1-980x807.jpg 980w, https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_infra_olho_seco_eyer2-1-480x395.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><figcaption class=\"wp-element-caption\">Meibografia realizada com o retin\u00f3grafo port\u00e1til Eyer2 utilizando m\u00f3dulo de segmento anterior<\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p>Devido ao alto custo dos aparelhos que realizam a meibografia, este exame, apesar de relevante para o diagn\u00f3stico e monitoramento de casos de olho seco evaporativo, ainda n\u00e3o \u00e9 t\u00e3o popular nos consult\u00f3rios oftalmol\u00f3gicos. Recentemente, a Phelcom inovou trazendo o registro por luz infravermelha para o port\u00e1til Eyer2, novo produto da empresa, tornando a realiza\u00e7\u00e3o da meibografia mais pr\u00e1tica e acess\u00edvel.<\/p>\n\n\n\n<p>O m\u00f3dulo de segmento anterior do Eyer2 permite realizar tanto a meibografia quanto exame para identificar altera\u00e7\u00f5es nas c\u00e9lulas epiteliais na c\u00f3rnea e conjuntiva, por meio da luz azul cobalto interagindo com a fluoresce\u00edna.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><a href=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_cobalto_eyer2.jpg\" data-lbwps-width=\"1600\" data-lbwps-height=\"1600\" data-lbwps-srcsmall=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_cobalto_eyer2-300x300.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_cobalto_eyer2-1024x1024.jpg\" alt=\"Img Cobalto Eyer2\" class=\"wp-image-34587\" style=\"width:509px;height:auto\" srcset=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_cobalto_eyer2-980x980.jpg 980w, https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_cobalto_eyer2-480x480.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><figcaption class=\"wp-element-caption\">Registro de les\u00e3o de c\u00f3rnea utilizando o retin\u00f3grafo Eyer2 associado a fluoresce\u00edna<\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p>\u00c9 recomend\u00e1vel que outras an\u00e1lises cl\u00ednicas sejam realizadas no processo de diagn\u00f3stico de olho seco, como por exemplo o teste de Schirmer, para diferencia\u00e7\u00e3o entre olho seco por defici\u00eancia de produ\u00e7\u00e3o e olho seco evaporativo.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Outros usos relevantes da meibografia<\/strong><\/h2>\n\n\n\n<p>A meibografia tamb\u00e9m \u00e9 recomendada no pr\u00e9-operat\u00f3rio de cirurgias refrativas, pois o olho seco, muitas vezes associado \u00e0 MGD, \u00e9 uma complica\u00e7\u00e3o comum ap\u00f3s esses procedimentos. Neste cen\u00e1rio, o exame serve como documenta\u00e7\u00e3o pr\u00e9-operat\u00f3ria e monitoramento das gl\u00e2ndulas, al\u00e9m de servir para fins educativos junto ao paciente.&nbsp;<\/p>\n\n\n\n<p>O m\u00e9dico tamb\u00e9m pode fazer uso da meibografia para avalia\u00e7\u00e3o de poss\u00edveis comprometimentos das p\u00e1lpebras pelo uso de lentes de contato, rea\u00e7\u00f5es por conjuntivite al\u00e9rgica, por tratamento antiglaucomatoso e outras condi\u00e7\u00f5es cl\u00ednicas.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong><strong>O Eyer2<\/strong><\/strong><\/h2>\n\n\n\n<p>A Phelcom acaba de lan\u00e7ar o <a href=\"https:\/\/phelcom.com\/pt-br\/produtos\/eyer2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Eyer2<\/a>, uma verdadeira plataforma de exames visuais que permite realizar registros dos segmentos posterior e anterior com alta qualidade de imagem.&nbsp;Al\u00e9m da meibografia por meio de luz infravermelha, o novo equipamento conta com retinografias coloridas e <em>red free<\/em> com campo visual de 55\u00ba e ferramentas para capturas do segmento anterior utilizando diferentes tipos de luz para exames de superf\u00edcie ocular, incluindo a luz azul cobalto, que permite avaliar les\u00f5es de c\u00f3rnea e conjuntiva.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><a href=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_eyer2_modulo_imantado-1.jpg\" data-lbwps-width=\"1700\" data-lbwps-height=\"1488\" data-lbwps-srcsmall=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_eyer2_modulo_imantado-1-300x263.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"896\" src=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_eyer2_modulo_imantado-1-1024x896.jpg\" alt=\"Img Eyer2 Modulo Imantado 1\" class=\"wp-image-34592\" style=\"width:777px;height:auto\" srcset=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_eyer2_modulo_imantado-1-980x858.jpg 980w, https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_eyer2_modulo_imantado-1-480x420.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><figcaption class=\"wp-element-caption\">Eyer2 com novo m\u00f3dulo para capturas de segmento anterior<\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sobre a Phelcom&nbsp;&nbsp;<\/h2>\n\n\n\n<p>A Phelcom Technologies \u00e9 uma medtech brasileira sediada em S\u00e3o Carlos, interior de S\u00e3o Paulo. A hist\u00f3ria da empresa come\u00e7ou em 2016, quando tr\u00eas jovens pesquisadores \u2013 um f\u00edsico, um engenheiro eletr\u00f4nico e um engenheiro de computa\u00e7\u00e3o (PHysics, ELetronics, COMputing) \u2013 criaram um retin\u00f3grafo port\u00e1til integrado a um smartphone.<\/p>\n\n\n\n<p>Em 2019, a Phelcom lan\u00e7ou no mercado brasileiro o seu primeiro produto: o retin\u00f3grafo port\u00e1til Eyer, vencedor dos pr\u00eamios&nbsp;<a href=\"https:\/\/phelcom.com\/pt-br\/blog\/empresa\/eyer-vence-wsa-2020\/\">World Summit Award 2020<\/a>&nbsp;e&nbsp;<a href=\"https:\/\/phelcom.com\/pt-br\/blog\/empresa\/smart-retinal-camera-vence-o-falling-walls-lab-sao-paulo-2016\/\">Falling Walls Lab 2016<\/a>.&nbsp;<\/p>\n\n\n\n<p>Hoje, a tecnologia dos produtos da Phelcom j\u00e1 alcan\u00e7ou mais de duas milh\u00f5es de pessoas em todo o Brasil e nos pa\u00edses em que est\u00e1 presente.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><sub>Fontes: <\/sub><br><sub>Wolffsohn et al. TFOS DEWS II Diagnostic Methodology report 2017<\/sub><br><sub>Magno et al. Hot towels: The bedrock of Meibomian gland dysfunction treatment \u2013 A review<\/sub><br><sub>Arita. Meibography: A Japanese Perspective Reiko. 2018<\/sub><\/p>\n","protected":false},"excerpt":{"rendered":"<p>As manifesta\u00e7\u00f5es cl\u00ednicas relacionadas ao olho seco s\u00e3o extremamente comuns entre os pacientes oftalmol\u00f3gicos, e a disfun\u00e7\u00e3o das gl\u00e2ndulas de Meib\u00f4mio (MGD) \u00e9 a causa mais comum, presente em 86% dos casos.<\/p>\n","protected":false},"author":24,"featured_media":34617,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[104],"tags":[],"class_list":["post-34569","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-inovacao"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco - PHELCOM Technologies<\/title>\n<meta name=\"description\" content=\"As manifesta\u00e7\u00f5es do olho seco s\u00e3o recorrentes em pacientes oftalmol\u00f3gicos, sendo a disfun\u00e7\u00e3o das gl\u00e2ndulas de Meib\u00f4mio (MGD) a mais comum.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco - PHELCOM Technologies\" \/>\n<meta property=\"og:description\" content=\"As manifesta\u00e7\u00f5es do olho seco s\u00e3o recorrentes em pacientes oftalmol\u00f3gicos, sendo a disfun\u00e7\u00e3o das gl\u00e2ndulas de Meib\u00f4mio (MGD) a mais comum.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/\" \/>\n<meta property=\"og:site_name\" content=\"PHELCOM Technologies\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/phelcom\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-05-06T13:44:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-02T14:38:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_olho_seco_eyer2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1700\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Fernanda Verardi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Fernanda Verardi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/\"},\"author\":{\"name\":\"Fernanda Verardi\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#\\\/schema\\\/person\\\/8f3e6adb5fb7d2d7f986a711804708b2\"},\"headline\":\"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco\",\"datePublished\":\"2024-05-06T13:44:41+00:00\",\"dateModified\":\"2024-10-02T14:38:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/\"},\"wordCount\":783,\"publisher\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/phelcom.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/img_olho_seco_eyer2.jpg\",\"articleSection\":[\"Inova\u00e7\u00e3o\"],\"inLanguage\":\"pt-BR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/\",\"url\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/\",\"name\":\"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco - PHELCOM Technologies\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/phelcom.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/img_olho_seco_eyer2.jpg\",\"datePublished\":\"2024-05-06T13:44:41+00:00\",\"dateModified\":\"2024-10-02T14:38:36+00:00\",\"description\":\"As manifesta\u00e7\u00f5es do olho seco s\u00e3o recorrentes em pacientes oftalmol\u00f3gicos, sendo a disfun\u00e7\u00e3o das gl\u00e2ndulas de Meib\u00f4mio (MGD) a mais comum.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/#primaryimage\",\"url\":\"https:\\\/\\\/phelcom.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/img_olho_seco_eyer2.jpg\",\"contentUrl\":\"https:\\\/\\\/phelcom.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/img_olho_seco_eyer2.jpg\",\"width\":1700,\"height\":900,\"caption\":\"Img Olho Seco Eyer2\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/blog\\\/inovacao\\\/meibografia-para-diagnostico-de-olho-seco\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/\",\"name\":\"PHELCOM Technologies\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#organization\",\"name\":\"Phelcom\",\"url\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/phelcom.com\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/color_horizontal.png\",\"contentUrl\":\"https:\\\/\\\/phelcom.com\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/color_horizontal.png\",\"width\":245,\"height\":40,\"caption\":\"Phelcom\"},\"image\":{\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/phelcom\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/phelcom-technologies\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCSZCLEV9ZrbGBie0R0IxQpA\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/phelcom.com\\\/pt-br\\\/en\\\/#\\\/schema\\\/person\\\/8f3e6adb5fb7d2d7f986a711804708b2\",\"name\":\"Fernanda Verardi\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco - PHELCOM Technologies","description":"As manifesta\u00e7\u00f5es do olho seco s\u00e3o recorrentes em pacientes oftalmol\u00f3gicos, sendo a disfun\u00e7\u00e3o das gl\u00e2ndulas de Meib\u00f4mio (MGD) a mais comum.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/","og_locale":"pt_BR","og_type":"article","og_title":"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco - PHELCOM Technologies","og_description":"As manifesta\u00e7\u00f5es do olho seco s\u00e3o recorrentes em pacientes oftalmol\u00f3gicos, sendo a disfun\u00e7\u00e3o das gl\u00e2ndulas de Meib\u00f4mio (MGD) a mais comum.","og_url":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/","og_site_name":"PHELCOM Technologies","article_publisher":"https:\/\/www.facebook.com\/phelcom\/","article_published_time":"2024-05-06T13:44:41+00:00","article_modified_time":"2024-10-02T14:38:36+00:00","og_image":[{"width":1700,"height":900,"url":"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_olho_seco_eyer2.jpg","type":"image\/jpeg"}],"author":"Fernanda Verardi","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Fernanda Verardi","Est. tempo de leitura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/#article","isPartOf":{"@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/"},"author":{"name":"Fernanda Verardi","@id":"https:\/\/phelcom.com\/pt-br\/en\/#\/schema\/person\/8f3e6adb5fb7d2d7f986a711804708b2"},"headline":"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco","datePublished":"2024-05-06T13:44:41+00:00","dateModified":"2024-10-02T14:38:36+00:00","mainEntityOfPage":{"@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/"},"wordCount":783,"publisher":{"@id":"https:\/\/phelcom.com\/pt-br\/en\/#organization"},"image":{"@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/#primaryimage"},"thumbnailUrl":"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_olho_seco_eyer2.jpg","articleSection":["Inova\u00e7\u00e3o"],"inLanguage":"pt-BR"},{"@type":"WebPage","@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/","url":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/","name":"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco - PHELCOM Technologies","isPartOf":{"@id":"https:\/\/phelcom.com\/pt-br\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/#primaryimage"},"image":{"@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/#primaryimage"},"thumbnailUrl":"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_olho_seco_eyer2.jpg","datePublished":"2024-05-06T13:44:41+00:00","dateModified":"2024-10-02T14:38:36+00:00","description":"As manifesta\u00e7\u00f5es do olho seco s\u00e3o recorrentes em pacientes oftalmol\u00f3gicos, sendo a disfun\u00e7\u00e3o das gl\u00e2ndulas de Meib\u00f4mio (MGD) a mais comum.","breadcrumb":{"@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/#primaryimage","url":"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_olho_seco_eyer2.jpg","contentUrl":"https:\/\/phelcom.com\/wp-content\/uploads\/2024\/05\/img_olho_seco_eyer2.jpg","width":1700,"height":900,"caption":"Img Olho Seco Eyer2"},{"@type":"BreadcrumbList","@id":"https:\/\/phelcom.com\/pt-br\/blog\/inovacao\/meibografia-para-diagnostico-de-olho-seco\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/phelcom.com\/pt-br\/"},{"@type":"ListItem","position":2,"name":"Meibografia: aux\u00edlio valioso no diagn\u00f3stico de olho seco"}]},{"@type":"WebSite","@id":"https:\/\/phelcom.com\/pt-br\/en\/#website","url":"https:\/\/phelcom.com\/pt-br\/en\/","name":"PHELCOM Technologies","description":"","publisher":{"@id":"https:\/\/phelcom.com\/pt-br\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/phelcom.com\/pt-br\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/phelcom.com\/pt-br\/en\/#organization","name":"Phelcom","url":"https:\/\/phelcom.com\/pt-br\/en\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/phelcom.com\/pt-br\/en\/#\/schema\/logo\/image\/","url":"https:\/\/phelcom.com\/wp-content\/uploads\/2018\/07\/color_horizontal.png","contentUrl":"https:\/\/phelcom.com\/wp-content\/uploads\/2018\/07\/color_horizontal.png","width":245,"height":40,"caption":"Phelcom"},"image":{"@id":"https:\/\/phelcom.com\/pt-br\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/phelcom\/","https:\/\/www.linkedin.com\/company\/phelcom-technologies","https:\/\/www.youtube.com\/channel\/UCSZCLEV9ZrbGBie0R0IxQpA"]},{"@type":"Person","@id":"https:\/\/phelcom.com\/pt-br\/en\/#\/schema\/person\/8f3e6adb5fb7d2d7f986a711804708b2","name":"Fernanda Verardi"}]}},"_links":{"self":[{"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/posts\/34569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/comments?post=34569"}],"version-history":[{"count":0,"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/posts\/34569\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/media\/34617"}],"wp:attachment":[{"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/media?parent=34569"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/categories?post=34569"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/phelcom.com\/pt-br\/wp-json\/wp\/v2\/tags?post=34569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}